The UCP-104 has 4 zones and can accommodate up to 32 conventional detectors and manual call points, with a maximum of four zones.

Coming with a robust metal body design, simple installation, and great performance

FEATURES & BENEFITS

EN 54-2 and EN 54-4 Certified
4 Zone Capacity with Full Monitoring
Each zone can have up to 32 conventional detectors
Indicator Panel that is simple to use and manage
Each zone has its own fire and error LEDs
Extending battery life with smart battery charging advanced feature.
Intelligent start feature that prevents starting directly from battery
Individually disabling for each zone
Monitoring Siren Outputs and Zone Inputs for any fault connections with EOL Resistances
Two 500mA Siren Outputs for a total of 50 sounder connections (if ULTRA UCSF-116 sounders are used)
24VDC 500mA external supply output with automatic fuse (AUX)
1x Fire Relay (NC/NO) (Button alarm, detector alarm, etc.)
1 x Error Relay (NC/NO) (Energy, Zone, and Battery Outage…etc)
Unauthorized access is prevented by using a key lock
SMPS (Switch Mode Power Supply): (27.6VDC SMPS 1.5Ah automatic fuse)

The UCP-108 supports 8 zones and can accommodate up to 32 conventional detectors and manual call points, with a maximum of eight zones.

Coming with a robust metal body design, simple installation, and great performance. The panel complies with all European Standards' technical requirements

FEATURES & BENEFITS

Each zone can have up to 32 conventional detectors
Indicator Panel that is simple to use and manage
Each zone has its own fire and error LEDs
Extending battery life with smart battery charging advanced feature.
Intelligent start feature that prevents starting directly from battery
Individually disabling for each zone
Monitoring Siren Outputs and Zone Inputs for any faulty connections with EOL Resistances
Two 500mA Siren Outputs for a total of 50 sounder connections (if ULTRA UCSF-116 sounders are used)
24VDC 500mA external supply output with automatic fuse (AUX)
1x Fire Relay (NC/NO) (Button alarm, detector alarm, etc.)
1 x Error Relay (NC/NO) (Energy, Zone, and Battery Outage…etc)
Unauthorized access is prevented by using a key lock
SMPS (Switch Mode Power Supply): (27.6VDC SMPS 1.5Ah automatic fuse)